Available Workflow Actions
|
|
If you were logged in you would be able to see more operations.
|
|
|
External
Created: 2008-04-24 03:13
Updated: 2008-04-24 03:13
|
|
| Component/s: |
Aastra
|
| Affects Version/s: |
None
|
| Fix Version/s: |
None
|
|
|
Original Estimate:
|
Unknown
|
Remaining Estimate:
|
Unknown
|
Time Spent:
|
Unknown
|
|
File Attachments:
|
1.
00085D1B44AE.cfg (5 kb)
2.
capture_port5060.pcap (125 kb)
|
|
Environment:
|
Firmware Version 2.1.0.2145
Firmware Release Code SIP
Boot Version 2.0.1.1055
Date/Time Jun 20 2007 06:55:26
Firmware Version 2.1.0.2145
Firmware Release Code SIP
Boot Version 2.0.1.1055
Date/Time Jun 20 2007 06:55:26
|
|
|
1) Add an aastra phone (571, 55i or 53i) to sipXconfig with default configuration.
2. Add a line to the phone.
3. Send profile to the phone
4. Set phone's tftp server to point to sipx and restart phone.
Phone does come up and values of all the parameters shown on the phone correctly as expected. However the phone does not get registered to sipx. When I put it on a sniffer, I found that the phone does not send any REGISTER requests out all.
To work around this, just set the proxy port and the registrar port values to zero.
|
|
Description
|
1) Add an aastra phone (571, 55i or 53i) to sipXconfig with default configuration.
2. Add a line to the phone.
3. Send profile to the phone
4. Set phone's tftp server to point to sipx and restart phone.
Phone does come up and values of all the parameters shown on the phone correctly as expected. However the phone does not get registered to sipx. When I put it on a sniffer, I found that the phone does not send any REGISTER requests out all.
To work around this, just set the proxy port and the registrar port values to zero. |
Show » |
| There are no comments yet on this issue.
|
|